Machinery monitoring

Pump Monitoring Guide

Quick one-page resource including recommended solutions to monitor pumps.

Fan Monitoring Guide

Quick one-page resource including recommended solutions to monitor fans.

Gearbox Monitoring Guide

Quick one-page resource including recommended solutions to monitor gearboxes.

Oil & Gas Applications

Quick one-page resource including recommended solutions for oil and gas applications.

In walk-around applications, can magnets be used with HFD techniques?2019-01-15T14:39:51+00:00

Yes. Although the lowered mounted resonance may cause attenuated signals in the HFD pass band. In addition, inconsistencies in use of the magnet may lower the confidence level of trend based readings. Previous trend data will be rendered invalid if the magnet size, sensor, or mounting technique is changed.

What are the important characteristics of a cementing pad installation?2019-01-15T14:38:25+00:00

Best efforts should be made to provide a flat spot face on the machine at the cementing pad location. The cement interface on both the pad and the machine must be abraded and solvent cleaned to optimize adhesion. Appropriate adhesives must be employed to protect the installation from failure due to chemical attack; high temperature, long term degradation; and, the rigorous demands of maintenance personnel.

What are the important characteristics of a stud mounted installation?2019-01-15T14:36:52+00:00

Best efforts must be made to provide a flat, smooth, and even surface (spot facing) at the sensor machine interface. The tapped hole must be perpendicular to the mounting interface. Gaps between the sensor and the mounting surface due to poor spot facing and drilling and tapping techniques can significantly lower the mounting resonance of the sensor. In addition, poor thread cutting can reduce the strength of the stud mount allowing the sensor to be more easily knocked off the machine during routine maintenance.

What are the preferred mounting methods for vibration sensors?2019-01-15T14:35:37+00:00

Optimum performance from the sensor will be achieved by stud mounting directly to the machine. Cementing pads may also be used with some reduction in the mounted resonance.

Magnets and probe tips are used in walk-around applications, but greatly limit the frequency response of the sensor.

Do multiplexed installations damage the sensor electronics?2019-01-15T14:33:18+00:00

No. The “filament effect” suggesting that sensor amplifiers fail like a light bulb from repeated switching on and off is a myth. Piezoelectric accelerometer amplifiers are high reliability, low power devices (typical draw is less than 100 mW). The transistors used are designed for long term use in switching applications—modern transistor technology is based upon the older TTL computers that performed billions of switching operations. Wilcoxon has extensively tested the Wilcoxon PiezoFET® in excess of two million switching operations without failure.

Can sensors be installed with multiplexed monitoring systems?2019-01-15T14:32:19+00:00

Yes. Multiplexing provides a convenient, cost effective way to take trend data and reduce cabling costs on permanently installed systems. Sensor turn-on time should be considered and a delay programmed into the multiplexing scheme to prevent ski slope of the first several bins of the spectrum.

What are the advantages of switchable junction boxes?2019-01-15T14:29:53+00:00

Junction boxes provide a cost effective transition between walk-around data collection and permanent on-line monitoring systems. They also improve job safety by removing the data taker from dangerous environments. In addition, the signal point switchable configuration reduces labor by decreasing data collection time.

How should two conductor shielded cables be grounded in Intrinsically Safe applications?2019-01-15T14:28:26+00:00

When using two conductor shielded cable from the sensor and a single barrier strip, the cable shield should be tied to machine ground through the sensor housing and terminated before the hazardous side of the barrier.

Where in the cable route should the barrier strip in Intrinsically Safe applications be located?2019-01-15T14:26:55+00:00

The barrier strip should be located outside the hazardous area and mounted near the junction box, multiplexer, or monitoring system. When using single barrier strips, the common signal carrier is grounded to the barrier enclosure; and therefore, must be in close proximity to monitor ground to prevent ground loops.

How long a cable can be run?2019-01-15T14:26:12+00:00

With standard powering and sensors available in today’s market, cables can generally be run to lengths of 200 feet without concern.Cable routes much beyond 200 feet are common and rarely effect the measurement. However, it is recommended that the sensor manufacturer be consulted to review the application to determine the suitability of long cable runs. Long cable runs cause capacitive loading at high frequencies increasing the sensors susceptibility to amplifier overload. The condition to be avoided is very long cables in the presence of high amplitude, high frequency signals when measuring low frequency, low amplitude signals.

How should the cable be secured?2019-01-15T14:25:35+00:00

At the sensor, the cable should be strain relieved with enough flex to allow full movement of the machine and ease removal during maintenance. When routing the cable, both conduit and cable tie downs are used in general practice. When using tie wraps, Tefzel® tie wraps may be required in some harsh environments such as paper machine installations.

Is there “crosstalk” between sensor cables when routed together?2019-01-15T14:24:54+00:00

Vibration signals from low impedance accelerometers do not crosstalk between cables in normal operation. In the rare application where very high amplitude signals are being carried next to very low amplitude signals, some crosstalk may occur. The attenuation between two conductor shielded cables in parallel contact with each other is greater than 100 dB.

How should the cable be routed near high current carrying wires?2019-01-15T14:24:19+00:00

In general, the cable should not be routed alongside or parallel to high current carrying wires. If the installation requires that the low signal carrying sensor cable be routed alongside the high current carrying wire, they should be separated by a minimum distance of six inches and preferably installed in a separate and grounded conduit or tray. High current carrying wires should be crossed at right angles only.

How should the cable shield be grounded?2019-01-15T14:23:42+00:00

When using coaxial cables, the shield carries common and therefore, is grounded at the monitoring system. The shield must be isolated from the sensor housing to prevent ground loops.
When using two conductor shielded cable, two methods are available.

  1. If the sensor housing, is electrically connected to the machine (i.e., stud mount), the cable shield is typically connected to the sensor housing and thereby tied to machine ground. In this type of installation, the shield should not be tied to the monitoring system or ground loops may develop between the monitor ground and the machine ground.
  2. If the sensor housing is electrically isolated from the machine (i.e., many cement mounting installations), then the shield should be tied to monitor ground. It is recommended that the shield be isolated from the sensor housing in this type of installation to prevent ground loops in the event that the isolation between the sensor housing and the machine is lost.

Read more at https://wilcoxon.com/resources/faqs/#db4ypC3dHZAILKMI.99

What is the preferred cable: two conductor shielded or coaxial?2019-01-15T14:22:52+00:00

Two conductor shielded is preferred for four reasons.

  1. Unlike coaxial cable where the shield is a signal carrier, two conductor signal carriers are enclosed by the shield and not directly exposed to electrical interference.
  2. The twist of the two conductors provides differential cancellation of magnetic interference.
  3. The stripped and tinned end of the two conductors is easier to connect into terminal block panels.
  4. Because the shield is isolated from the signal carriers, more advanced grounding techniques may be applied. Coaxial cables should only be used if BNC or other types of coaxial connectors are required for the installation.
How does corrosive chemicals and solvents affect the accelerometer?2019-01-15T14:22:09+00:00

Corrosive chemicals and solvents can contaminate signal conductors causing intermittent signals and eventually destroy the sensor housing, connector, and cabling. In industrial environments, the sensor housing should be built of chlorine resistant, 316L stainless steel. Teflon®, Tefzel®, and Viton® connector and cabling materials should also be used due to their strong chemical resistance at high temperatures. Neoprene and polyurethane may be acceptable in benign environments.

How does near machine mechanical noise affect the accelerometer?2019-01-15T14:21:33+00:00

Near machine mechanical noise from cavitating pumps and steam/gas leaks can produce very high frequency, high amplitude signals (i.e., hiss). This mechanical noise can overload the sensor and produce low frequency distortion giving the appearance of an exaggerated ski slope response. Even low level mechanical noise (such as passing trucks) can interfere with very low frequency measurements.

How does electrostatic discharge affect the accelerometer?2019-01-15T14:20:51+00:00

Electrostatic discharge can produce false signals and damage the sensors electronics if not properly protected. Case isolation, internal shielding, and two conductor shielded cable will attenuate electrostatic interference from arcing motors and other electrical impulses. Transient voltage suppressors should be built into the amplifier to prevent permanent damage to semiconductors in the electronics.

How does electromagnetic interference affect the accelerometer?2019-01-15T14:20:17+00:00

Electromagnetic interference can produce false signals at the sensors output. Very high frequency electromagnetic interference can cause intermodulation distortion and produce low frequency measurement errors. The internal electronics and sensing element of the accelerometers should be case isolated for the prevention of ground loops and electronically shielded to attenuate electromagnetic fields. Two conductor shielded cable is preferred over coaxial cable.

How do humidity and/or possible immersion affect the accelerometer?2019-01-15T14:19:39+00:00

Humidity and immersion can cause intermittent shorting of the signal carriers on epoxy sealed sensors and poorly designed or specified connector/cable assemblies. The intermittent shorting will produce spurious signals that trigger alarms or cause the sensor to fail. In industrial applications, metal to metal and glass to metal hermetically sealed sensors should be used. The connector/cable assembly should be designed to resist liquid intrusion. When using splash-proof or immersion proof connectors, silicone grease should be applied to the contacts to further protect the connection.

How do transient temperatures affect the accelerometer?2019-01-15T14:18:54+00:00

Fast transient temperature changes may cause spurious signals on the sensor output due to thermal expansion of the metal parts. When using poorly designed or specified sensors these spurious outputs can trigger false alarms. Low frequency accelerometers and sensors with poor strain sensitivity are much more susceptible to transient temperature effects.

How does ambient temperature affect the accelerometer?2019-01-15T14:18:17+00:00

The accelerometer sensitivity will shift over the rated temperature range of the sensor (usually by less than 10%). The shifts are trendable and do not cause any permanent changes in the sensor. When subjected to very high temperatures at the limit of the temperature range, the sensor must be designed for long term exposure by utilizing high reliability electronics.

What environmental effects should be considered for an accelerometer installation?2019-01-15T14:11:22+00:00

The primary environmental effects to be considered are:

ambient temperature temperature transients humidity and/or possible liquid immersion electromagnetic interference electrostatic discharge near machine mechanical noise corrosive chemicals and solvents

How do piezoelectric sensors compare with proximity probes and electrodynamic velocity sensors?2019-01-15T14:10:28+00:00

Proximity probes provide very strong relative displacement outputs at low frequencies. However, they are difficult to install and, due to filtering in their electronics, give very little information at higher frequencies.

The electrodyamic velocity sensors provide very strong absolute velocity measurements at mid-band frequencies. However, they are nonlinear at frequencies below 10 Hz (600 cpm) and contain moving parts that can wear and fail. Their useful frequency range is, typically, 10 Hz to 1,000 Hz.

Piezoelectric sensors provide strong absolute acceleration signals over a very wide frequency range. They are extremely rugged, easy to install, and can provide a variety of outputs depending upon the application.

What are the differences between general purpose and low frequency accelerometers?2019-01-15T14:09:28+00:00

Low frequency accelerometers employ a larger seismic mass to increase the output from the sensing element assembly. This reduces the electronic noise from the amplifier and allows higher voltage outputs from the sensor. The higher voltage outputs of low frequency sensors help overcome data collector noise when measuring low amplitude signals. The tradeoff is a lowering of the resonance frequency.

What are the primary types of sensors used in industrial applications?2019-01-15T14:08:45+00:00

General purpose accelerometers (100 mV/g), low frequency accelerometers (500 mV/g), and piezovelocity transducers (100 mV/ips) are specified depending upon the machine speeds, amplitude levels and measurement techniques employed. The primary goal in sensor selection is maximization of the signal-to-noise ratio of the measurement.

What determines the amplitude range?2019-01-15T14:07:50+00:00

The difference between the power supply and the bias voltage and the ground and the bias voltage determines the amount of AC voltage the amplifier can swing (amplitude range). When using sensors with 12 volt bias, it is generally recommended that the supply voltage exceed 24 volts to increase the amplitude range performance of the sensor. Multiplying the sensitivity of the sensor by the available voltage swing gives the amplitude range in terms of engineering units (g, ips, etc.).

What is the bias voltage?2019-01-15T14:07:01+00:00

The bias voltage, sometimes referred to as the rest voltage, is required to measure AC signals using two wire single ended amplifiers. The DC bias voltage provides a carrier on which the AC signal is superimposed. It is generally chosen at a point half way between the power supply and ground.

How do you lower amplifier noise?2019-01-15T14:05:52+00:00

Low noise components should be used, but the most effective way to lower amplifier noise is to decrease amplifier gain. This is done by using high output sensing element assemblies most notably, through the use of piezoceramic sensing elements.

What is electronic amplifier noise?2019-01-15T14:05:11+00:00

All electronic components produce some electrical noise. At high frequencies, amplifier noise is governed by circuit resistors in the form of Johnson Thermal or white noise. Low frequency noise is governed by transistors and other active components in the form of 1/f noise. This is why the noise is higher at very low frequencies, slopes down and becomes flat at high frequencies.

With the higher output sensitivity, won’t a low frequency sensor overload easily?2019-01-15T14:04:22+00:00

With their high sensitivity output and consequently lower amplitude range, low frequency/ high output sensors are vulnerable to overload especially in the presence of significant high frequency vibration. For this reason, Wilcoxon includes a low-pass filter within the electronics of these Wilcoxon sensors. This filter controls the high-end frequency cut-off and attenuates the high frequency signals. By not processing the high frequency (and often high vibration level) data, there is less chance of sensor overload.

Do 500 mV/g sensors just have more internal electronic gain than a general purpose (100 mV/g) sensor?2019-01-15T14:02:39+00:00

No. A sensor with additional electronic gain will produce the desired effect of increasing the amplitude of vibration output of the low level signal. However, this technique will also produce the undesired effect of increasing the level of the noise within the sensor. The only technique to increase the sensitivity without increasing the noise is to mechanically gain the signals. Mechanical gain is accomplished by increasing the sensor mass (low frequency sensors are generally heavier than other sensors) and /or using a higher output sensing crystal. All Wilcoxon low frequency, high output sensors use mechanical gain.

Can general-purpose 100 mV/g accelerometers be used for slow-speed machinery measurements?2019-01-15T14:01:58+00:00

While many general-purpose 100 mV/g accelerometers carry a low frequency -3dB specification of 0.2 Hz to 0.5 Hz, they are not the best choice for accurate measurements on slow-speed machines. That is because most general-purpose 100 mV/g accelerometers also have a much higher low frequency noise level than accelerometers designed for low frequency measurements. The 500 mV/g low frequency accelerometers should be used as they have much better signal-to-noise ratios.

hy don’t all vibration sensors have low frequency response?2019-01-15T14:00:55+00:00

A high pass filter is inherent to electronics of all piezoelectric accelerometers. The filter has a resistor and capacitor in series and the value of these components, RC, determines the low-end cut-off. Also known as the discharge time constant (DTC), the larger the RC value, the lower the frequency response. The DTC also defines the sensor response to abrupt changes in sensor powering such as turn-on and signal overload. When the sensor is turned on or begins to recover from an overload, the time it takes to become usable is directly related to the DTC value. Therefore, the low end cut-off is inversely proportional to the turn-on time (and shock recovery time). In other words, the lower in frequency the sensor measures, the longer it takes to turn-on or recover from an overload. For general-purpose sensors, the low-end frequency performance is sacrificed in favor of better turn on and shock recovery response.

Can general-purpose 100 mV/g accelerometers be used for slow-speed machinery measurements?
While many general-purpose 100 mV/g accelerometers carry a low frequency -3dB specification of 0.2 Hz to 0.5 Hz, they are not the best choice for accurate measurements on slow-speed machines. That is because most general-purpose 100 mV/g accelerometers also have a much higher low frequency noise level than accelerometers designed for low frequency measurements. The 500 mV/g low frequency accelerometers should be used as they have much better signal-to-noise ratios.

Is a shear mode sensor superior to compression mode?2019-01-15T14:00:03+00:00

What about flexure mode sensors? In recent years, shear mode sensors have gained popularity, while compression mode are often considered to be “old technology.” Meanwhile, flexural mode sensors, once considered too fragile for industrial applications, are now making a comeback by incorporating special design techniques. Each construction method has inherent advantages and disadvantages. The construction method of a sensor is less important than its performance.For each model, characteristics such as base strain and shock limits are quantified on the specification sheet and can be compared. For example, a well-designed compression mode sensor may have a lower base strain rating than a shear mode sensor. While this may be contrary to many peoples’ intuition, it can be verified by comparing the values of the 793 (compression) versus the 786A (shear). In today’s advanced designs, the right sensor for an application is determined by the performance yielded by different design techniques.

How long do piezoelectric sensors last?2019-01-15T13:59:17+00:00

Piezoelectric sensors are solid state sensors with no internal moving parts to wear or fatigue. Mean Time Between Failure (MTBF) analysis for typical industrial sensors predicts a life of 12 years. However, many Wilcoxon Sensing Technologies sensors returned to Wilcoxon for re-calibration are more than 30 years old and still operating. While many sensors do indeed last beyond a decade, empirical data suggests an average life of approximately 15 to 20 years. If a sensor is continuously operated to the full limits of their environmental specifications, then their life span can be decreased. Sensors exposed to high temperatures (> 200ºF) and rough handling are candidates for earlier failures than those permanently mounted in benign environments.

Will a wide sensitivity tolerance (±15% vs. ±5%) mean a narrower frequency response?2019-01-15T13:57:22+00:00

No. Sensor frequency response is based on sensitivity variation relative to the sensitivity at the 100 Hz reference point. Whether the reference sensitivity is 105 mV/g or 85mV/g, the frequency at which the sensor sensitivity increases/decreases by a specified amount (ie. 10% or 3dB) remains constant.

Is a wider sensitivity tolerance bad, such as ±15%?2019-01-15T13:44:54+00:00

No, if trending on vibration levels then wider tolerances, such as ±15%, provides adequate, cost effective information for a successful monitoring program. Also, nearly all data collection boxes, analyzers and acquisition systems have the ability to enter the exact sensitivity of a sensor. In these cases, purchasing a sensor with a wide tolerance is acceptable as long as its sensitivity is appropriately noted. However, if the user is unable to enter the exact sensitivity and the acquisition equipment assumes a nominal sensitivity, then a precise measure of the vibration level may not be possible. For example, if the acquisition equipment assumes the vibration signal is obtained from a 100mV/g sensor and the actual sensor being used is 85 mV/g, the vibration readings will be 15% low. In this case, a tighter tolerance (±5%) may be more appropriate. If possible, enter the exact sensitivity of the sensor into the acquisition system to obtain the most precise measurements.

Can an iT Series module operate at 12VDC, for battery-applications?2019-01-15T13:43:36+00:00

Yes, within limits. Without the recommended +24VDC power, there is insufficient voltage to operate a typical 2-wire IEPE sensor, but the transmitter can certainly operate off +12VDC supply with 3-wire capacitively-coupled sensors. The communication module also operates at +12VDC. The alarm can be special-ordered with 12VDC relays (instead of typical +24VDC relays). Contact Wilcoxon for more information. Note that no certification currently exists for these modules at low-voltage operation.

What accessories are there for the iT Series?2019-01-15T13:42:35+00:00

Wilcoxon offers DIN enclosures, power supplies, TBUS connectors, fuses and custom cables to complete the iT Series. We have developed a great guide to all of the accessories, “iT051 Mounting Box and Configurations.” This guide details the setup and required accessories to start an iT Series solution. It discusses the size of the DIN enclosure and modules, as well as which TBUS connectors are correct for each setup. It also gives current, voltage, and power supply information.

What certifications are there for the iT Series modules?2019-01-15T13:40:25+00:00

Wilcoxon iT Series modules are certified by CSA for CE-compliance. Additional certifications may be possible with proper junction-box enclosures and barrier devices.

Why would the iT Series generally be used instead of other techniques?2019-01-15T13:39:28+00:00

Generally, 4-20 mA vibration monitoring is used for equipment that ought to be monitored for vibration, but where access or infrequent servicing is an issue. The iT modules present options for installing vibration monitoring. The transmitter allows a 4-20 mA signal to be used for simplified monitoring, while preserving access to the full bandwidth of an accelerometer for detailed vibration spectrum analysis.

The iT Alarm allows for local alarm and shutdown capability. The fact that the IT401 can be used with either the iT Transmitter or any 4-20 mA sensor offers users greater flexibility. A system can be built for monitoring that utilizes both vibration and process variables for alarming.

Many plant process computers have already utilized all available analog input channels. Adding even just a couple more analog channels may be prohibitively expensive. With the iT Alarm, the local processing offered by a combination of an iT Transmitter with an iT Alarm allows the use of spare digital inputs to the plant process computer. Frequently, there are many unused digital inputs when the analog inputs are full.

Why would someone use a vibration transmitter when loop-powered 4-20 mA sensors are available?2019-01-15T13:38:42+00:00

If the only need is to have a loop-powered sensor for monitoring the overall vibration, then sensors like the Wilcoxon 4-20 mA LPS® series will suffice. However, if very low or very high frequency monitoring is desired, the iT Transmitter series is necessary because they have the wide frequency response required. Also, a transmitter is required when it is desired to trend vibration in a limited portion of the frequency spectrum, but have the full spectrum available for detailed FFT analysis.

Can the latched alarm be remotely acknowledged?2019-01-15T13:37:54+00:00

Yes. There is an input on the module for a remote reset using dry contacts.

There are no potentiometers to adjust on the iT Alarm. What does a user access to make alarm setting adjustments?2019-01-15T13:36:59+00:00

The front panel has three “membrane” switches. These are used to access and change the settings for the alarm. They are also used to acknowledge an alarm to reset a latched relay.

Why does the iT Alarm only have two-digits for a display?2019-01-15T13:36:11+00:00

Cost, size, and power-dissipation of more digits are some of the mechanical reasons, but the main reason is accuracy of the display.  True, integer values of 4-20mA are potentially large steps, but the display is 1%-accurate when in “percentage-mode.” 1%-steps equates to 0.16mA accuracy!

The iT Alarm has a digital display. What is possible to display on it?2019-01-15T13:22:05+00:00

During normal operation the display can be set to indicate the current in the sensor loop in terms of integer values of milliamps, from 2 to 25 mA. It can also be set to display in terms of 0% to 99% of the full-scale 4-20 mA input or transmitter input.

Why is the iT Alarm module separate, can’t it just be part of the iT Transmitter module so there’s only one module?2019-01-15T13:21:00+00:00

If the alarms were integral to the transmitter, then the overall cost would be higher and many users would buy a function they do not want.  There are also several features that result from the alarm being a separate module:

  1. Modularity allows several alarm units to operate off of one signal source.
  2. The alarm is able to directly operate small motors and valves, eliminating the need to link up with a PLC or DCS.  Only the iT Alarm uses power relays with the capacity to switch 250 VAC, 8A-resistive or 1/3HP inductive machines.
  3. Having the alarm as a separate unit allows using it with an LPS® 4-20mA vibration sensor or any 4-20mA sensor such as temperature, pressure, level, flow, force or speed.
iT Alarm highlights:2019-01-15T12:53:21+00:00

The iT Alarm includes three programmable relays – high and low setpoints, and a BOV monitor to alert the customer when a sensor or cable connection malfunctions. Each relay can be user-programmed independently to activate if the signal exceeds user-defined limits. The iT Alarm connects directly to a plant PLC or DCS network to provide additional capability in process control programs.

Each relay can be user-programmed with delay timers up to 99 seconds to eliminate false alarms that may result from temporary irregular vibrations (such as those that occur when a machine is starting up). Users can set hysteresis levels, allowing alarms to remain active if vibration levels have not returned to normal, but dropped below the alarm setpoint.  Each relay can be user-programmed to 1%-accurate high and low alarm setpoints, with a 1V-accurate windowing for a third, BOV-type alarm.

Is the sensitivity or internal integration of the iT Transmitter field-programmable?2019-01-15T12:50:51+00:00

Yes, for the iT300 series. The sensitivity, internal integration, frequency range, output type, and 4-20mA parameters are all field-programmable via Ethernet.

For the iT100/200 series, these features are all selected at the time of purchase and cannot be modified in the field.

Can the Dynamic Output be AC-coupled or DC-coupled in an iT Transmitter module?2019-01-15T12:49:47+00:00

Yes, in the iT100/200 series. Jumper J10 exists inside the transmitter to select AC- or DC-coupling of the buffered sensor output. AC-coupling makes the output +/- with reference to common, DC-coupling makes the output +/- with respect to ½ of the power supply (not sensor BOV).

The iT300 series is automatically DC-coupled.

Is the dynamic output (BNC, TBUS, or wired-plug) buffered from the sensor?2019-01-15T12:49:05+00:00

Yes. A fault on the TBUS, dynamic-output socket, or front-panel BNC will not impair the 4-20mA loop-current determination from a sensor.

Does the fuse inside an iT Transmitter adequately protect the modules?2019-01-15T12:47:19+00:00

The fuse is designed to protect the main transmitter module connected to the power supply – in the event too many modules or a module-fault exists anywhere on the TBUS connector. The fuse provides adequate protection if you supply power to the input power-connector of the transmitter module. The fuse is NOT adequate if you supply power directly to the TBUS-connector using a wired-plug.

If the “manual” mode for setting the filter frequencies is used, is there a way to know for sure what frequency the potentiometer is set to select?2019-01-15T12:46:33+00:00

There is no way to determine exactly what frequency the potentiometer is set once the filter frequencies have been modified, unless the user has some sort of frequency monitoring device that can be connected to the transmitter output.

If the monitoring frequency is expected to be modified, it is recommended to use the iT300 series for manual entry and ease of configuration.

What kind of filtering exists inside the iT Transmitters?2019-01-15T12:45:53+00:00

The transmitter modules contain 2-6 poles of “real” high-pass (low-frequency) filtering, depending on calibration frequency. The modules contain 9-12 poles of “real” low-pass (high-frequency) filtering, based on calibration frequency. RC-filters, multiple-feedback (active) filters, and switched-capacitor filters ensure low-power operation with no digital artifacts in the processed signal.

I have a 3-wire (power, common, signal-out) sensor that is biased from 0-5VDC, ±5VDC, or ±10VDC. Can I use the iT Transmitters with this?2019-01-15T12:40:57+00:00

Absolutely. The transmitter modules contain jumpers which allow you to switch from IEPE (2-wire sensor operation) to 3-wire operation. You may need to capacitivety-couple the signal-output of your sensor. Contact Wilcoxon Applications Engineering for assistance.

What’s the TBUS?2019-01-15T12:40:57+00:00

The TBUS is a rear-board connector on each module in the iT Series. The transmitter modules place 24 VDC power onto the TBUS along with digital and analog signals. The transmitter only transmits digital data; it does not receive any digital data from the TBUS. In turn, the alarm module only receives data from the TBUS. They do not transmit data to the transmitter through the TBUS. The alarm module also receive its power through the TBUS connection.

If two, or more, iT Transmitter modules share a sensor, can they be set up with different parameters?2019-01-15T12:40:57+00:00

Yes. The transmitter modules have a provision for sharing a sensor. Also, the TBUS can be used for this sharing as one of the TBUS lines is for the analog sensor signal sharing. IT100/200 Series Transmitter manual contains the details for setting up the sharing arrangement.

What output options are available with the iT Transmitter?2019-01-15T12:40:57+00:00

Output of 4-20 mA data is offered in terms of r.m.s., peak, and now also in Wilcoxon’s exclusive true peak and true peak-to-peak.  True peak detection is ideal for measuring short duration vibration, when it is most important to capture and hold maximum absolute instantaneous events.  True peak-to-peak detection is designed for use with displacement measurements, which captures and holds the maximum total vibration.  The 4-20 mA loop output signal can also represent the true root-mean-square (r.m.s.) value of the vibration signal or the equivalent peak vibration (obtained by multiplying by the ratio of peak to r.m.s., 1.414).   Peak and r.m.s. detection are best for general machine health monitoring, when overall vibration is measured.

But I don’t have a vibration analyst on staff. Can I still use the iT Series?2019-01-15T12:40:57+00:00

Continuous online monitoring is available to large and small facilities alike. For facilities that have a control or monitoring system which accepts 4-20mA analog signals, such as a PLC or DCS, these analog input channels are all that is needed to add the benefit of vibration monitoring to your process control. Plants that do not have an existing process monitoring system in place can use the relay capability present in the iT301 or monitor the dynamic output through the use of a data collector.

Moreover, trending of the overall vibration level does not require any sophisticated analysis skills. Observing a sustained increase in overall vibration usually provides enough evidence to warrant a more detailed inspection of the machine.

What if my application is special?2019-01-15T12:40:57+00:00

The iT Series allows maintenance professionals to create a custom vibration monitoring center.  Each iT 100 or 200 Series Transmitter is built to user-selected specifications, with options for online monitoring and data trending for every facility, regardless of budget or size.

Options include a selectable full-scale with English or metric units, measurement outputs of acceleration, velocity or displacement, four different outputs of RMS, Peak, Peak-to-Peak and True Peak, and various frequency ranges over which to monitor. The iT300 series allows users to field configure their parameters for maximum flexibility. All of the aforementioned options are configurable via Ethernet, giving the power to manually enter, modify and test transmitter configurations directly to the user. The iT300 Series also provides a secondary 4-20mA output signal to double the measurement power, while some of the higher-series models offer Modbus support and alarm relay capability.

For which applications is the iT Series right?2019-01-15T12:40:57+00:00

The iT Series is appropriate for industrial, commercial, and municipal facilities that all benefit from machinery health monitoring programs. If physical plant assets are doing the work to process a product, then increases in productivity and efficiency can be realized with a continuous online machinery health monitoring program.

Some of the most common processes to benefit from the iT Series are pharmaceutical, food and beverage, brewing, water and waste water, petrochemical, pulp and paper, and power generation facilities.  The iT Series is effective for monitoring pumps, motors, fans, cooling towers, compressors, and gear boxes. Applying predictive maintenance techniques to these operations and machines can result in significant maintenance expense reductions.

What is the Intelligent Transmitter Series?2019-01-15T12:40:57+00:00

The Intelligent Transmitter (iT) Series is a complete family of units that provide signal conditioning for simplified online vibration monitoring and provide a Total Lower Cost approach to continuous monitoring. The iT Series includes the iT Transmitters and iT Alarm.

  1. The iT Transmitter is a signal conditioning module that interfaces with a traditional IEPE accelerometer to provide a 4-20 mA output signal and a buffered dynamic signal.  This allows the user to interface an accelerometer with a PLC, DSC or similar system for condition trending, while still providing a dynamic output for more extensive vibration analysis through the BNC connector on the front of the module.  The iT Transmitter can be ordered with custom settings to meet user-specific requirements, or with field-configurable settings that can be changed via the front panel Ethernet port where available.  iT Transmitter models have part numbers in the iT100, iT200 ranges and iT300 ranges.
  2. The iT Transmitter pairs with the iT Alarm, a DIN-rail mountable alarm with three programmable relays for use in vibration monitoring or process control systems.  The iT401 Alarm, which compares the 4-20mA input from the transmitter against user-defined high or low setpoints, triggers the relays and/or provides an alert when the input deviates from acceptable levels.  The front panel controls and digital LED readout make this unit very user friendly.  The real advantage of this unit is that it can also be used with any 4-20mA sensor including pressure, temperature, flow, speed and especially Wilcoxon’s popular LPS® vibration sensors.

Read more at https://wilcoxon.com/resources/faqs/#PUfazk7RQj2emGeL.99